FB-5060 Access Door Description

 
The Acudor FB-5060 is approved by Underwriters Laboratories (UL) for 1-1/2 hours "B" label in walls and ULC for 2 hours "B" label in walls. Designed to maintain continuity in a 2-hour fire barrier wall, the FB-5060 should be used whenever it is necessary to provide access in fire rated walls, when temperature rise is not a factor. For drywall applications, this door is available with galvanized steel drywall taping bead flange. (FB-5060-DW)

Access Door Specifications

Access Door Material:

  Steel or Stainless Steel: 16 gage door, 16 gage mounting frame.

Access Door:

  Flush to frame with reinforced edges.

Access Door Frame:

  Flanged to be 1" wide, mounting frame to have anchor straps. (optional).

Access Door Hinge:

  Concealed.

Access Door Fire Rating:

  UL - 1-1/2 hour "B" label. ULC - 2 hour "B" label. (optional)

Access Door Latch:

  Universal self-latching bolt, operated by either a knurled knob or flush key. When master keying is required, doors can be prepared for rim cylinder locks or mortise cylinder locks.

Access Door Finish:

  Steel: 5-stage iron phosphate preparation with prime coat of gray baked enamel.
Stainless Steel: #4 satin polish.

 

access doors

 

STANDARD SIZE ACCESS DOORS (special sizes available upon request)

NOMINAL DOOR SIZE
W&H
CEILING OR WALL
OPENING
NO. OF
LATCHES
WEIGHT PER DOOR
FB-5060
INCHES
mm
INCHES
mm
.
lbs.
kg.
8x8
203x203
8-3/8x8-3/8
213x213
1
5.5
2.5
10x10
254x254
10-3/8x10-3/8
264x264
1
6.7
2.9
12x12
305x305
12-3/8x12-3/8
365x365
1
8.3
3.8
14x14
355x355
14-3/8x14-3/8
365x365
1
9.5
4.3
16x16
406x406
16-3/8x16-3/8
416x416
1
11.5
5.2
18x18
457x457
18-3/8x18-3/8
467x467
1
14.3
6.5
22x30
560x762
22-3/8x30-3/8
568x772
1
32.5
14.5
22x36
560x914
22-3/8x36-3/8
568x924
2
28
12.7
24x24
610x610
24-3/8x24-3/8
619x619
1
20.3
9.2
24x36
610x914
24-3/8x36-3/8
619x924
2
28.5
12.9
24x48
610x1220
24-3/8x48-3/8
619x1229
2
34
10.6
30x30
762x762
30-3/8x30-3/8
772x772
2
28.5
12.9
36x36
914x914
36-3/8x36-3/8
924x924
2
38
17.2
36x48
914x1220
36-3/8x48-3/8
924x1229
2
47.5
21.5


__________________________________

FW-5050 Access Door Description

 
The Acudor FW-5050 is a fire rated access door approved for use in walls and ceilings. For walls, this door has a Underwriters Laboratories (UL and ULC), 1-1/2 hour "B" label, with a maximum temperature rise of 250 degrees after 30 minutes. This door should be used in walls when temperature rise or heat transmission is a factor.
For fire rated ceilings, this door has been approved by Warnock Hersey International for 3 hours (max. size to 24" X 36"). For drywall applications, this door is available with a galvanized steel drywall taping bead flange. (FW-5050-DW)

Access Door Specifications

Access Door Material:

  Steel or Stainless Steel: 20 gage door, 16 gage mounting frame.

Access Door:

  Filled with 2" thick fire rated insulation.

Access Door Frame:

  Flange to be 1" wide, mounting frame to have anchor straps (optional).

Access Door Hinge:

  Concealed.

Access Door Fire Rating:

  Walls - UL/ULC 1-1/2 hour "B" label with 250 degree temp. rise. Ceilings - Warnock Hersey International - 3 hours.

Access Door Latch:

  Universal self-latching bolt, operated by either a knurled knob or flush key. When master keying is required, doors can be prepared for mortise cylinder locks.

Access Door Finish:

  Steel: 5-stage iron phosphate preparation with prime coat of gray baked enamel.
Stainless Steel:  #4 satin polish.

 

access doors

 

STANDARD SIZE ACCESS DOORS(special sizes available upon request)

NOMINAL DOOR SIZE
W&H
CEILING OR WALL
OPENING
NO. OF
LATCHES
WEIGHT PER DOOR
FW-5050
INCHES
mm
INCHES
mm
.
lbs.
kg.
8x8
203x203
8-3/8x8-3/8
213x213
1
8
3.6
10x10
254x254
10-3/8x10-3/8
264x264
1
9
4.1
12x12
305x305
12-3/8x12-3/8
365x365
1
10
4.8
14x14
355x355
14-3/8x14-3/8
365x365
1
12
5.4
16x16
406x406
16-3/8x16-3/8
416x416
1
15
6.8
18x18
457x457
18-3/8x18-3/8
467x467
1
20
9.1
22x30
560x762
22-3/8x30-3/8
568x772
1
32
14.5
22x36
560x914
22-3/8x36-3/8
568x924
2
35
15.9
24x24
610x610
24-3/8x24-3/8
619x619
1
28
12.7
24x36
610x914
24-3/8x36-3/8
619x924
2
38
18.1
24x48
610x1220
24-3/8x48-3/8
619x1229
2
48
21.3
30x30
762x762
30-3/8x30-3/8
772x772
2
38
18.1
36x36
914x914
36-3/8x36-3/8
924x924
2
54
24.5
36x48
914x1220
36-3/8x48-3/8
924x1229
2
76
34.5


__________________________________

FW-5050-UP Access Door Description

 
The Acudor FW-5050-UP is a fire rated inward opening access door approved for use in ceilings. This door has been approved by Warnock Hersey International for 3 hours (Available in 3 sizes 24”x24”, 22”x36” & 24”x36”).

An Upswing
Fire Rated Access Door!

 


[PRINTABLE VERSION]

Access Door Specifications

Access Door Material:

  Steel or Stainless Steel: 14 gage door, 14 gage mounting frame.

Access Door:

  Flush to edge of frame.

Access Door Frame:

  Expansion casing bead with 3" wide galvanized lath, recessed 3/4" to receive plaster.

Access Door Hinge:

  Continuous, concealed.

Access Door Latch:

  Stainless Steel screwdriver operated cam latch. Also available: cylinder lock and key, allen head cam latch, spanner head cam latch.

Access Door Finish:

  teel: 5-stage iron phosphate preparation with prime coat of gray baked enamel.
Stainless Steel: #4 satin polish.

 



__________________________________

 

 

Acudor Products, Inc.
Toll Free: 800-722-0501

(Coporate Offices)
80 Little Falls Road
Fairfield, NJ 07004
Tel: 973-575-5120
Fax: 973-575-5160
E-mail: info@acudor.com
(Western Region)
4126 North Pecos Rd., Suite 104
Las Vegas, NV 89115
Tel: 702-644-8710
Fax: 702-644-8720
E-mail: LVsales@acudor.com